MAX SET GAS VALVE
Max Set Gas Valve
Max Set Gas Valve-1001 is used to set air/gas ratio on a nozzle-mix burner. It has a V-port plug that can be adjusted sensitively and accurately with a screwdriver. Turning the screw counterclockwise increases flow. A cap conceals the adjustment and discourages tampering with the setting. If an adjustment is needed, replace top cap on valve body to reduce air or gas leaks.
The V-port adjustment is in a removable gas cartridge assembly, simplifying inspection or replacement. Max set gas valves have brass internals; 1001-K Valves have iron internals for coke gas and others corrosive to brass; 1001-TK Valves are for hot gases.
Capacity Scfh |
1001 - 01 ½” | 1001 - 0 ¾” | 1001 - 1 1" | 1001 -2 1¼" | 1001 -3 1½" | 1001 - 4 2" | 1001 - 5 2½" | 1001-6 3” | Specific Gravity | Capacity factor |
---|---|---|---|---|---|---|---|---|---|---|
0.2 | 086 | 121 | 0222 | 0327 | 0414 | 0990 | 1491 | 2600 | 0.4 | 01.22 |
0.3 | 122 | 172 | 0315 | 0470 | 0584 | 1400 | 2110 | 3675 | 0.6 | 01.00 |
0.5 | 149 | 210 | 0386 | 0564 | 0715 | 1720 | 2580 | 4500 | 0.8 | 0.866 |
0.6 | 172 | 243 | 0446 | 0650 | 0830 | 1980 | 2982 | 5200 | 1.5 | 0.632 |
0.8 | 192 | 272 | 0500 | 0730 | 0925 | 2230 | 3340 | 5820 | 2.0 | 0.547 |
2.0 | 272 | 385 | 0705 | 1030 | 1310 | 3150 | 4720 | 8220 | ||
3.0 | 384 | 542 | 0990 | 1460 | 1850 | 4450 | 6660 | 11590 | ||
5.0 | 470 | 665 | 1210 | 1780 | 2270 | 5440 | 8200 | 14220 | ||
7.0 | 544 | 770 | 1410 | 2060 | 2620 | 6300 | 9440 | 16440 | ||
9.0 | 610 | 860 | 1580 | 2320 | 2930 | 7040 | 10560 | 18400 | ||
10.0 | 666 | 940 | 1720 | 2550 | 3210 | 7700 | 11570 | 20150 |